| No LED is on, the unit is switched on and is supplied with operating current | Automatic restart is blocked (e.g. after a power failure) | Reset the unit: switch off, wait 5 seconds, then switch on again |
| No LED illuminates after switching on | No operating voltage | Check 12V battery voltage, charge battery if necessary |
| Device fuse or vehicle fuse defective | Check all electrical plug connections |
| The green LED comes on when the unit is switched on, but the heating system does not operate | The temperature setting on the control panel is lower than the room temperature | Select a higher room temperature on the control panel |
| After switching on the heating system, the green LED illuminates and the yellow LED flashes once (heating system continues to operate) | Risk of low voltage – battery voltage < 10.4 V | Charge the battery |
| Yellow LED flashes 2 times (heating system not operating) | Low voltage – battery voltage < 10.0 V | Charge the battery, replace it if necessary |
| Overvoltage > 16.4 V | Check battery voltage and voltage sources such as the charger |
| Yellow LED flashes 3 times | Open window above cowl (window switch) | Close the window in the dining area |
| Yellow LED flashes 4 times (after operating for a longer period of time, the heating system switches to failure) | Summer mode with empty water container | Switch unit off, allow it to cool down and fill the boiler with water |
| Warm air outlets blocked | Check and clear all air outlets |
| Circulated air intake blocked | Remove any blockage from the air intake |
| Yellow LED flashes 5 times | Room temperature sensor or cable defective | Contact Customer Service |
| Yellow LED flashes 7 times | Control panel or control panel cable defective | Contact Customer Service |
| Yellow LED flashes 8 times | FrostControl heating element short-circuited | Contact Customer Service |
| Yellow LED flashes 9 times (approx. 30 seconds after switching on) | Gas cylinder or quick-acting valve closed | Check gas supply and open valves |
| Gas cylinder empty | Replace gas cylinder |
| (After operating for a longer period of time, the heating system switches to failure) | Gas pressure regulator iced up or too much butane in the cylinder | Use propane (butane is unsuitable below 10°C) |
| Red LED flashes 1–8 times | Heating system fault | Contact Customer Service |
| Green LED flashes (5 Hz) after the heating system has been switched off | After-running is active to cool down the unit | No fault — after-run stops automatically after max. 5 minutes |
| Room heating does not react immediately to adjustments | After-running is active | No fault — after-run stops automatically after max. 5 minutes |
| After switching on, the green and the red LED illuminate | Faulty electronics | Contact Customer Service |