Truma CP Classic Panel (Gas) – Error codes & Troubleshootings

  • 1.  Outer control knob for heating mode
  • 2.  Inner control knob for temperature (1 – 5)
  • 3. Yellow LED lit, “Boiler heat-up phase”
  •     Yellow LED flashing “Warning”
  •     Red LED lit, red LED flashing “Fault”
  • 4. Green LED lit, “On”
  • 5. Hot water mode – temperature 60 °C
  • 6. Hot water mode – temperature 40 °C
  • 7. Rotary switch “Off”
  • 8. Air heating mode
  • 9. Air heating and hot water mode

Faults – Causes – Rectification

FaultCauseRectification
No LED is on, the unit is switched on and is supplied with operating currentAutomatic restart is blocked (e.g. after a power failure)Reset the unit: switch off, wait 5 seconds, then switch on again
No LED illuminates after switching onNo operating voltageCheck 12V battery voltage, charge battery if necessary
Device fuse or vehicle fuse defectiveCheck all electrical plug connections
The green LED comes on when the unit is switched on, but the heating system does not operateThe temperature setting on the control panel is lower than the room temperatureSelect a higher room temperature on the control panel
After switching on the heating system, the green LED illuminates and the yellow LED flashes once (heating system continues to operate)Risk of low voltage – battery voltage < 10.4 VCharge the battery
Yellow LED flashes 2 times (heating system not operating)Low voltage – battery voltage < 10.0 VCharge the battery, replace it if necessary
Overvoltage > 16.4 VCheck battery voltage and voltage sources such as the charger
Yellow LED flashes 3 timesOpen window above cowl (window switch)Close the window in the dining area
Yellow LED flashes 4 times (after operating for a longer period of time, the heating system switches to failure)Summer mode with empty water containerSwitch unit off, allow it to cool down and fill the boiler with water
Warm air outlets blockedCheck and clear all air outlets
Circulated air intake blockedRemove any blockage from the air intake
Yellow LED flashes 5 timesRoom temperature sensor or cable defectiveContact Customer Service
Yellow LED flashes 7 timesControl panel or control panel cable defectiveContact Customer Service
Yellow LED flashes 8 timesFrostControl heating element short-circuitedContact Customer Service
Yellow LED flashes 9 times (approx. 30 seconds after switching on)Gas cylinder or quick-acting valve closedCheck gas supply and open valves
Gas cylinder emptyReplace gas cylinder
(After operating for a longer period of time, the heating system switches to failure)Gas pressure regulator iced up or too much butane in the cylinderUse propane (butane is unsuitable below 10°C)
Red LED flashes 1–8 timesHeating system faultContact Customer Service
Green LED flashes (5 Hz) after the heating system has been switched offAfter-running is active to cool down the unitNo fault — after-run stops automatically after max. 5 minutes
Room heating does not react immediately to adjustmentsAfter-running is activeNo fault — after-run stops automatically after max. 5 minutes
After switching on, the green and the red LED illuminateFaulty electronicsContact Customer Service